Closed

New build Milford Diagnostics Centre for MRI and CT Diagnostics Imaging at Milford Hospital

Descriptions

The Royal Surrey NHS Foundation Trust propose to develop a new-build facility for Magnetic Resonance Imaging (MRI) and Computed Tomography Imaging (CTI) at the Milford Hospital, Tuesley Lane, Godalming, Surrey GU7 1UF. The building is single-storey with a link corridor to the existing Rehabilitation Building at Milford Hospital. The building also has plant rooms and a service yard with an acoustic fence to accommodate the mechanical and electrical services at the rear. Associated works include the construction of a new access road from Tuesley Lane that will be initially used for construction, and on completion will be re-surfaced for maintenance, servicing, deliveries and access for waste-bin vehicles. Also proposed is the provision of additional car parking for 18 cars, 3 motorbikes, and 6 bicycle racks, the erection of an electricity substation, and the installation of foul drainage and attenuation soakaway for SUDS drainage The site was considered suitable and viable for this facility as it would help the Royal Surrey NHS Foundation Trust in its quest to be become a pre-eminent cancer hub in the South-East of England. Milford Hospital already provides plain X-Ray and ultrasound facilities and the location of MRI and CT diagnostic imaging will suitably complement the existing facilities and widen the scope of available diagnostic imaging services across the Royal Surrey Hospital sites. Milford Hospital lies in a site of approximately 2.3hectares. It accommodates a 1980s ward block known as the Rehabilitation Building having an area of 1,764m2, a 1½ storey newly refurbished X-Ray block of 122m2, a two-storey Victorian building for Community Services Management offices, a small, detached building shed and a redundant building. The site for the new diagnostics centre is the grassed area to the east of the Rehabilitation Building and bounded by a wooded strip to the north and the east towards Tuesley Lane. The new Milford Diagnostics Building is 1,963.15m2 consists of: · Clinical Facilities: o 2no MRI Scanner Rooms, Control Rooms, Engineering Technical Rooms o 1no CT Scanner Room, Control Room o Patient Cannulation Rooms o Counselling and Interview Rooms o Recovery Rooms o Patient Changing Rooms o Patient WCs o Clean and Dirty Utility Rooms · Staff and Non-Clinical Facilities o Reception o Main Waiting Room o Sub-Waiting Room for CT o Offices o Staff Changing Rooms o Staff WCs · Mechanical and Electrical Services o Service Yard o Plant Room o Generator Room o Medical Gas Storage o Low Voltage Electrical Room o Oil Bunding Tank o Service Void floor in the roof space above the ground floor accommodation with 3no roof access shafts into the service void. o Bin Enclosure o Acoustic Fencing Associated works consist of: · External...

Timeline

Published Date :

5th Aug 2022 2 years ago

Deadline :

31st Aug 2022 2 years ago

Contract Start :

1st Feb 2023

Contract End :

1st Feb 2024

Tender Regions

Let’s Get you Started ✍

Get to see all tender details more briefly

Already have an account ?

Workflows

Status :

Closed

Assign to :

Tender Progress :

0%

Details

Notice Type :

Open opportunity

Tender Identifier :

IT-378-246-T: 2024 - 001

TenderBase ID :

310724019

Low Value :

£100K

High Value :

£1000K

Region :

North Region

Attachments :

Buyer Information

Address :

Liverpool Merseyside , Merseyside , L13 0BQ

Website :

N/A

Procurement Contact

Name :

Tina Smith

Designation :

Chief Executive Officer

Phone :

0151 252 3243

Email :

tina.smith@shared-ed.ac.uk

Possible Competitors

1 Possible Competitors